# Oura Ring 4 lost 26% of HRV readings in stress study

Source: https://idevice.com/oura-ring-4-lost-26-of-hrv-readings-in-stress-study
Published: 2026-11-26

> Oura's ring measured HRV more accurately than two rival wearables in a University of British Columbia study, but about one in four readings went missing.

[Oura Ring 4](https://idevice.com/smart-rings/oura/roadmap/ring-4) lost about a quarter of its HRV readings in a new lab stress study. The ones it kept were more accurate than those from two rival wearables. HRV, short for heart rate variability, is the tiny change in timing from one heartbeat to the next, and it feeds Oura's Daytime Stress feature.

A team at the University of British Columbia ran the test on 62 people and published the results on November 20 in the journal JMIR Biomedical Engineering, [Gadgets & Wearables reported](https://gadgetsandwearables.com/2026/11/26/oura-ring-4-daytime-hrv-accuracy-study/). Four wearables took part: the Oura Ring 4, the Nowatch X, the Empatica EmbracePlus and the Nuanic smart ring. Each was checked against lab equipment, including an ECG, which reads the heart's electrical signal directly.

To raise stress on cue, the researchers had people do maths in their heads, take memory tests and sing. Short rests between tasks let the team see how each wearable followed stress as it rose and fell.

On plain heart rate, Oura finished behind the two watches. It was off by an average of 2.48 beats per minute, against 1.87 for the Nowatch X and 1.42 for the Empatica EmbracePlus.

On HRV the ring came out ahead. Oura's average error was 7.17 milliseconds on RMSSD, a common way of scoring heart rate variability. The Nowatch X missed by 13.17 milliseconds and the Empatica by 19.77, so the ring's error was just over half of the nearest rival's.

Then about 26% of Oura's HRV readings never arrived, against 10% of its heart rate readings.

Empatica did worse, with about 53% of its HRV data missing. All of this happened while people stayed fairly still. The researchers also used Oura's unguided measurement session, not the background monitoring the ring does through a normal day. Throwing out shaky measurements keeps the remaining numbers clean, but it can leave holes that make a short spike of stress harder to catch.

Daytime Stress takes HRV, mixes it with heart rate, temperature and movement, and compares the result with what's normal for you. Oura says openly that it struggles to measure stress when you're moving around a lot. Missing HRV readings are one reason a stress graph has blank stretches.

The researchers tested the readings that feed Daytime Stress, not the stress score itself, so they didn't measure how well Oura covers a missing HRV reading with its other sensors.

If you wear an Oura Ring 4, trust the HRV number when it appears. A blank stretch in your daytime stress graph can mean the ring didn't get a usable reading, and it doesn't mean you were calm. Oura also leaves gaps while you sleep or move, and when the ring is off or fits loosely. Sleep is still where Oura's HRV tracking is strongest, so the overnight figure is the one to lean on.